Fanuc Power Supply Alarm Codes — Alpha Series

Original Post on FANUC Power Supply Alarm Codes.

View our FANUC Power Supplies Available.

Recently we had a customer who was working on troubleshooting a Fanuc power supply alarm that he had on a machine. He was wondering what the different codes stood for, so we wanted to go ahead and list the different alarm codes for this series. These codes apply to power supplies that start with the following prefixes. The “X”s after the H will be numbers, so an example part number is A06B-6087-H130.

A06B-6081-HXXX
A06B-6083-HXXX
A06B-6077-HXXX
A06B-6091-HXXX
A06B-6120-HXXX
A06B-6140-HXXX
A06B-6110-HXXX

Here is a list of the alarm codes for these series of Power Supply Modules.

AL01: The main circuit power module (IPM) has detected am Error (PSM-5.5,-11)
Overcurrent flows into the input of the main circuit (PSM-15 to –30).

AL02: A cooling fan for the control circuit has stopped.

AL03: The Temperature of the main circuit heat sink has risen abnormally.

AL04: In the main circuit the DC voltage (DC Link) has dropped.

AL05:The main circuit capacitor was not recharged within the specified time.

AL06: The Input Power Supply is abnormal (open phase).

AL07: In the main circuit the DC Voltage at the DC link is abnormally high.

Like what you read? Give MRO Electric a round of applause.

From a quick cheer to a standing ovation, clap to show how much you enjoyed this story.