Where is an Electrical Rubber Mat Used in a ship?

--

Photo by Vidar Nordli-Mathisen on Unsplash

Electrical mats are extensively used in the marine industry as electrical safety equipment. Ships are incorporated with complex electrical systems as they remain in the water. High voltage areas in the ship demand insulated safety matting to prohibit electrical hazards.

What is the working voltage of the electrical system in a ship?

Ships contain low, medium, and high-voltage systems. The low voltage systems comprise low-power devices, lighting, or other minimalistic systems. These systems have a working voltage of up to 1 kV. On the other hand, the medium voltage systems are concerned with propulsion systems, certain onboarding systems, as wells as other machineries that require more power than that of low voltage systems. These systems demand a working voltage that ranges up to 15 kV. However, high-voltage systems in a ship encompass operations in high-power propulsion systems and machinery along with tankers. Working voltage in a high voltage system of a ship can be beyond 15 kV too.

Why is it important to install electrical mats on ships?

Electrical safety matting operates like protective safety equipment in ships for people who are wired to work with high voltages. It is also known as a high voltage mat. Often the workplace being subjected to high voltage may result in unwanted conduction of electricity through the ship flooring. This might result in electric shock that is hazardous for the people dedicated to electrical equipment operations. The electrical hazard protection mat does not let the electricity conduct through the bodies of the workers. They work as a shield against shock and prevent accidents in ships.

Image by Duratuf Products

An anti-slip electrical safety mat is used to reduce the risks of skidding or slipping on the floor of the ship. This prohibits unnecessary health damage and accidents by creating more traction on the floor. Workers standing for prolonged hours while conducting operations on the ship can be provided with cushioning under their feet with the help of electrical safety matting.

There are many high-voltage areas in a ship that require insulating mats for electrical work. An electric mat is a dielectric mat that has the potential to withstand high voltage and will not easily have a dielectric breakdown. An anti shock mat not only reduces the risks of electric shock but also increases the productivity of the workers.

Where is electrical safety matting used in a ship?

  1. Electrical Switchboards and Panels- Electrical switchboards and panels have electrical distributing systems that work at high voltage. Thus, with the help of electrical mats, the workers can be protected from electrical hazards. It prevents electric shock during live electrical work.
  2. Engine Rooms- Engine rooms comprise a variety of high-voltage equipment. They are oriented with machinery, switchboards, propulsion systems, as well as transformers. An industrial safety mat is widely used in these areas for the prevention of shock.
  3. Battery Rooms- Battery rooms may deal with unnecessary leakage of electricity. With the help of electrical mats, live electrical work can be done efficiently with safely.
  4. Workshops- Workshops contain an ample amount of electrical equipment that works at a very high voltage. These areas require shock prevention. With the help of a high-voltage mat, the safety of the workshops can be ensured.
  5. Generator Rooms- Generator rooms contain generators and switch gears that have high working voltage. This area of the ship requires electrical hazard protection by the application of insulated safety matting.
  6. Machinery spaces- Power distribution equipment, motors operating at high voltage as well as controllers are predominant in machinery spaces. These heavy machineries operate in high voltage. As a result, insulated floor mat helps in enhancing insulation.
  7. HVAC systems- HVAC systems refer to Heating, Ventilation, and Air Conditioning systems. It comprises motors, control systems, and compressors that operate at high voltage. Electrical mats are essential to be implemented for electrical insulation against high voltage as it is an antishock mats.
  8. Cargo handling areas- Conveyor systems, machinery, and other cargo handling equipment are present in cargo handling areas. These areas can be exposed to electric current overflow. Electrical safety matting is instrumental in being implemented in these areas for safety purposes.
  9. Control rooms- Control rooms have several electrical equipment for the fundamental monitoring of the systems present in a ship. They are vulnerable to electrical leakage. Insulated safety matting can be used to prevent any electrical hazards.

Thus it can be summarized that electrical mats are significant in the marine industries. Insulated matting has a broad range of applications in different areas of the ships such as control rooms, generator rooms, machinery spaces, and others. It helps in shock prevention during the operation of live electrical work.

It reduces electrical hazards in the areas of the ships that have high working voltage. Insulated matting acts as an electrical safety equipment with exceptional insulating properties. Anti-slip electrical safety mat also helps in reducing the counts of accidents caused due to slipping and skidding.

--

--

Duratuf Products - Rubber Products Supplier

India's leading insulating mat, rubber sheet, conveyor belt & cow mat supplier with 3023+ happy clients, 10327+ successful project completion.