New Data Unveiled at Heart Rhythm 2020 Demonstrate Effectiveness of App-Based Remote Monitoring

Medtronic announced results from late-breaking clinical trials evaluating the MyCareLink Heart™ mobile app and the Micra® Transcatheter Pacing System (TPS), products that provide needed care for patients and optimal management of their symptoms — while reducing potential exposure between patients and their clinicians.

PulseLine
PulseLine
4 min readMay 15, 2020

--

During the current COVID-19 pandemic, procedures and therapies that reduce exposure to other people are important because that also reduces the potential for spreading the virus. The results were presented at the annual Heart Rhythm Society Scientific Sessions, held virtually for the first time.

Results from the BlueSync™ Evaluation study demonstrated that patients who used the Medtronic MyCareLink Heart mobile app (MCLH), a remote monitoring application on a patient’s phone or tablet, were more likely to adhere to their pacemaker remote monitoring schedule than patients who used traditional bedside monitors.

The study found that patients using the MCLH technology successfully completed 94.6% of scheduled transmissions, which was superior to all three Medtronic bedside monitor control groups (whose results ranged from 56.3% to 87.1%).

Higher patient adherence to scheduled transmissions of remote monitoring suggests that patients who use the MCLH app are more likely to benefit from remote monitoring than those with low or no adherence to remote monitoring.

Numerous peer-reviewed, published studies have demonstrated the benefits of remote monitoring; it has been shown to:

  • provide earlier detection and evaluation of patient clinical and device related events1–4,
  • reduce in-person clinic visits with no change in patient safety5–8,
  • improve patient quality of life 9–11 and
  • be associated with improved long-term patient survival12–14.

Medtronic introduced the world’s first remote cardiac monitoring system in 2002, and it has been embraced by two million patients worldwide. Because remote monitoring helps limit in-person contact between patients, caregivers and physicians, it potentially reduces exposure to bacteria and viruses, including the virus that causes COVID-19.

“Remote monitoring for cardiac health is associated with better patient outcomes and is playing an important role in the care of patients during the COVID-19 pandemic as in-person clinic visits are restricted, ” said Rob Kowal, M.D., Ph.D., chief medical officer of the Cardiac Rhythm and Heart Failure division, which is part of the Cardiac and Vascular Group at Medtronic. “These findings are very promising for this first-of-its-kind technology, suggesting patients using this app-based approach are more likely to successfully transmit the important remote cardiac device data that physicians need to manage their patients.”

Micra TPS CED Study
Results from the Micra Coverage with Evidence Development (CED) Study showed that patients implanted with a Micra TPS experienced a 66% reduction in chronic complications at six months compared with patients who received a traditional transvenous VVI pacemaker (TV-VVI). These results provide the first insight into the real-world comparative effectiveness of Micra TPS in the U.S. Medicare population, and represent the largest evaluation of leadless pacemakers to date.

“These results show that Micra’s lower likelihood of complications in earlier clinical trials is being maintained in real-world practice,” said Jonathan P. Piccini, M.D., associate professor of medicine and director of cardiac electrophysiology at Duke University Medical Center.

The Micra TPS is the first and only leadless pacemaker option available globally. Micra does not require leads or a surgical “pocket” under the skin, so potential sources of complications related to leads and pockets are eliminated — which may reduce in-office or hospital visits, an important consideration during this pandemic.

About the Studies
The full recorded late-breaking presentations on the BlueSync Evaluation and Micra CED studies can be accessed at Heart Rhythm 365.

The BlueSync Field Evaluation was a prospective, multicentre study measuring the success rate of scheduled transmissions in pacemaker patients using the MCLH mobile app for 12 months. Scheduled transmission success was compared to 3 distinct groups of bedside monitor device users from the Medtronic de-identified CareLink™ database.

Compatible with Medtronic BlueSync technology-enabled cardiac devices, the MCLH mobile app is designed to securely and wirelessly send cardiac device data to the Medtronic CareLink™ network via a patient-owned phone or tablet, eliminating the need for a dedicated bedside monitor or other remote monitoring hardware.

The Micra Coverage with Evidence Development Study evaluated device performance in 5,746 U.S. Medicare patients implanted with a Micra TPS and 9,662 U.S. Medicare patients implanted with a traditional pacemaker (TV-VVI, regardless of manufacturer) using claims data from the Centers for Medicare & Medicaid Services.

Along with a significant reduction in complication rates, Micra TPS patients also had a reduction in the rate of device revision compared to patients implanted with a TV-VVI device. While event rates are low, cardiac effusion and/or perforation within 30 days was higher among Micra TPS patients than transvenous patients in both unadjusted and adjusted models (unadjusted, 0.8% vs. 0.4%, P<0.001; adjusted, 0.8% vs. 0.4%, P=0.002); however, results were consistent with findings from the Micra TPS investigational device exemption (IDE) study and post approval registry.

1. Circ Arrhythm Electrophysiol. 2010;122:325–332.
2. J Am Coll Cardiol. 2011;57:1181–1189.
3. J Med Internet Res. 2013;15(8):e167
4. Circ Arrhythm Electrophysiol. 2010;3:428–436
5. Eur Heart J. 2014;35:98–105.
6. Circulation. 2010;122:325–332.
7. Eur Heart J. 2012;33:1105–1111.
8. Eur Heart J. 2013;34: 605–614
9. Eur Heart J. 2014;35:98–105.
10. Circulation. 2012;125:2985–2992.
11. Eur Heart J. 2012;33:1105–1111
12. Circulation. 2010;122:2359–2367
13. J Interv Card Electrophysiol. 2016:46(2):129–36
14. J Am Coll Cardiol. 2015;65:2601–2610.

--

--